Setup/installation profile light/section sensors

Standard installation

Standard sensor installation is at a right angle (90°) towards the reference surface respectively the object if no reference surface is present.

 

Defining the measuring field in standard installation

"Left" and "Right" is defined from the sensor’s point of view when looking at the connector outlet.

 

The sensor will detect objects and edges at a distance from 150 … 250 mm (z axis) and within the measuring range (x-axis) from  -62.5 mm to +62.5 mm (at 250 mm distance).

The reference surface or the object must be located within the measuring range, i.e. within the maximum distance of 250 mm (or less).


Angled installation

Angled sensor installation is with +/- 30° inclination towards the reference surface. This installation method is recommended in confined installation space leaving no other mounting option.

The reference surface or the object must be within the measuring range, i.e. within the maximum distance of 250 mm (or less).

 

Defining the measuring field in angled installation

At the maximum permitted inclination ±30°, the sensor will detect objects and edges within the measuring field defined below.
"Left" and "Right" is defined from the sensor’s point of view when looking at the connector outlet.